PTAC Air Conditioner 7,000–15,000 BTU | YUJU EnvironTech
PTAC Packaged Terminal Air Conditioners
7,000–15,000 BTU Cooling & Heating Solutions for Hotels, Apartments and Individual Rooms
Compact through-the-wall PTAC systems with low-noise operation, heat pump options, electric heat and simplified maintenance.
YUJU PTAC air conditioner available in multiple capacities for individual-room cooling and heating applications.
PTAC units combine cooling, air circulation and optional heating functions in a compact through-the-wall system.
Their independent room control, simple installation and accessible service design make them suitable for hotels, apartments and other buildings where each room requires individual temperature control.
Available Capacities
7,000 / 9,000 / 12,000 / 15,000 BTU
Multiple capacity options for different room sizes and project requirements.
Key Features
Low-Noise Design
The PTAC system uses an optimized blower wheel with a diameter of approximately Ø120 × 700 mm, designed to operate at a lower rotational speed.
A vibration-isolated rotary compressor helps reduce operating vibration and sound transmission.
Depending on operating condition and model configuration, indoor sound levels can be as low as approximately 35/45 dB(A).
Room Freeze Protection
Freeze-protection control helps protect rooms and building services during cold conditions.
When indoor temperature falls to approximately 50°F, the unit can automatically activate the fan and electric heating function and raise the room temperature toward approximately 55°F.
Heat Pump & Electric Heating
Heat pump models can provide both cooling and heating for year-round room comfort.
Standard electric heater options include:
- 3.0 kW electric heater
- 5.0 kW electric heater
- Available with applicable fixed-speed and inverter models
- Applicable across selected 7,000–15,000 BTU series
Instant Heat Mode
In applicable heat pump models, the electric heater can operate first during initial heating demand to provide faster room warm-up.
The system can then transition to heat pump operation as normal heating conditions are established.
Easy Installation
The PTAC design uses an integrated chassis and indoor/outdoor sub-assembly structure to simplify installation and equipment replacement.
This packaged configuration reduces the need for extensive refrigerant piping compared with conventional split-system installations.
Simple Maintenance
The unit is designed for convenient access to major service components.
- Integrated chassis
- Sealed electrical control box
- Removable nylon mesh filter
- Accessible internal components
- Simplified routine cleaning and service
Integrated PTAC design supports cooling, heating and straightforward room-side maintenance.
Typical Applications
- Hotels and motels
- Serviced apartments
- Student housing
- Dormitories
- Senior living facilities
- Residential apartments
- Individual offices and rooms
- Renovation and replacement projects
Why PTAC for Hotel & Apartment Projects?
PTAC systems allow each room to operate independently, which can simplify temperature control in buildings with many individual rooms.
| Feature | Project Benefit |
| Independent Room Control | Each room can set its own operating temperature. |
| Packaged Design | Reduces complex field refrigerant piping. |
| Service Access | Routine service can be performed from the room side. |
| Multiple Capacities | Different room sizes can use appropriately selected units. |
| Heating Options | Heat pump and electric heat options support different project requirements. |
PTAC Replacement Projects
PTAC units are frequently used in hotel and apartment renovation projects where older room air conditioners need to be replaced.
Before selecting replacement equipment, the existing wall opening, sleeve dimensions, electrical supply and heating requirements should be checked.
- Existing PTAC size and wall opening
- Required cooling capacity
- Heat pump or cooling-only requirement
- Electric heater capacity
- Voltage and frequency
- Room quantity
- Existing sleeve and grille conditions
- Control requirements
OEM & Project Support
YUJU EnvironTech supports HVAC distributors, importers, hotel projects and property customers with PTAC equipment selection and project supply.
Depending on the selected product platform and order requirements, OEM and private-label configurations can also be coordinated.
- 7,000–15,000 BTU model selection
- Heat pump configurations
- Electric heater options
- Fixed-speed or inverter platforms where available
- Project quantity planning
- OEM and private-label support
- Production coordination
- International shipping support
Planning a PTAC Project?
Send us the destination country, room quantity, required cooling capacity, heating requirement, voltage and existing installation dimensions.
YUJU can review the project requirements and recommend an appropriate PTAC configuration from available product platforms.
YUJU EnvironTech
PTAC Solutions for Hotels, Apartments & Replacement Projects
7K–15K BTU | Heat Pump | Electric Heat | OEM | Project Support



Scan Contact Us