R32 DC Inverter Rooftop Package Unit | YUJU EnvironTech
R32 DC Inverter Rooftop Package Unit
15 SEER2 & 18 SEER2 Packaged Heat Pump Solutions
Integrated cooling, heating, air circulation and filtration with DC inverter technology and R32 refrigerant.
R32 DC inverter rooftop packaged HVAC unit for residential and commercial heating and cooling applications.
The YUJU rooftop package unit combines refrigeration, heating, air circulation and air treatment functions within a compact outdoor cabinet.
DC inverter technology allows the system to adjust output according to actual building demand, while R32 refrigerant supports modern high-efficiency HVAC applications.
High Energy Efficiency
The rooftop package unit is available in high-efficiency configurations including 15 SEER2 and 18 SEER2 models, with selected configurations reaching up to 19 SEER2.
DC inverter compressor control allows system capacity to adjust according to the actual cooling or heating load instead of operating continuously at full output.
- DC inverter compressor technology
- Variable-capacity operation
- High-efficiency heat exchanger
- ECM outdoor and blower motors
- Direct evaporative refrigeration
- Improved part-load performance
R32 Refrigerant
The system uses R32 refrigerant as part of its high-efficiency refrigeration platform.
R32 is increasingly used in modern air-conditioning and heat pump equipment for applicable international markets.
Refrigerant selection, installation procedures and applicable market requirements should be confirmed according to the destination country and selected product model.
Quiet Operation
ECM outdoor fan and blower motors help provide smoother airflow and lower operating noise.
Because the refrigeration and air-moving equipment is installed outdoors, indoor areas primarily require the supply and return duct system, helping reduce indoor mechanical noise and save usable space.
Horizontal & Downflow Installation
The rooftop package unit supports both horizontal and downflow air-distribution configurations, allowing it to adapt to different building layouts.
| Configuration | Application |
| Downflow | Supply and return ducts connect downward through the rooftop curb into the building. |
| Horizontal | Side duct connections support projects where horizontal air distribution is required. |
A universal curb design can also help simplify installation and selected rooftop replacement applications.
Reliable Outdoor Design
The rooftop cabinet is designed for outdoor installation with weather-resistant construction, insulation and sealing to protect major internal components.
A dedicated electrical control section helps reduce exposure of control components to moisture and roof leakage.
- High-pressure protection
- Low-pressure protection
- Overload protection
- Phase-loss protection
- Over-temperature protection
Dehumidification Performance
Direct evaporative cooling allows the conditioned air to pass directly across the cooling coil, combining sensible cooling and moisture removal within the same air-treatment process.
The system is designed to support stable humidity control in applications with significant moisture loads or humid outdoor conditions.
Multiple HVAC Functions
Different rooftop configurations can be selected according to project requirements.
- Cooling-only configuration
- Heat pump heating and cooling
- Return-air operation
- Fresh-air options
- Dehumidification
- Air filtration
- Air circulation
Service-Friendly Design
The integrated refrigeration and ventilation structure simplifies the overall equipment arrangement.
Single-side service access on applicable configurations provides easier access to major components for inspection, troubleshooting and replacement.
This is particularly valuable for commercial rooftop equipment where minimizing service time can help reduce maintenance disruption.
Typical Applications
- Retail stores
- Restaurants
- Office buildings
- Hotels
- Schools
- Fitness centers
- Commercial spaces
- Selected residential applications
- Renovation and replacement projects
New Construction & RTU Replacement
Rooftop packaged units are suitable for both new buildings and selected replacement projects.
For replacement applications, matching the existing unit dimensions and duct connection arrangement can significantly reduce field modification.
- Existing RTU model
- Cooling and heating capacity
- Overall equipment dimensions
- Roof curb dimensions
- Supply and return openings
- Horizontal or downflow configuration
- Airflow and static pressure
- Voltage, phase and frequency
- Fresh air requirement
Typical Rooftop HVAC Airflow
Return Air / Fresh Air
↓
Filter
↓
R32 DC Inverter Rooftop Unit
↓
Cooling / Heating / Dehumidification
↓
Supply Air Duct
↓
Conditioned Space
Certified Performance
Applicable product configurations are available with AHRI-certified performance and ETL listing according to the selected model and market requirement.
Certification status should be confirmed during product selection, especially for North American projects.
What Buyers Should Confirm Before Ordering
- Required cooling and heating capacity
- SEER2 requirement
- Airflow and external static pressure
- Horizontal or downflow installation
- Voltage, phase and frequency
- Fresh air requirement
- Refrigerant requirement
- Required certification
- Replacement curb dimensions where applicable
- Project quantity and delivery schedule
YUJU Rooftop HVAC Project Support
YUJU EnvironTech supports HVAC distributors, contractors, importers and project buyers with rooftop packaged HVAC equipment for international markets.
Project support can include equipment selection, airflow configuration, electrical matching, efficiency requirements, replacement review and customized product coordination.
- R32 DC inverter rooftop package units
- 15 SEER2 and 18 SEER2 configurations
- Horizontal / downflow options
- Cooling-only or heat pump systems
- Fresh air configurations
- Replacement project review
- OEM and private-label support
- Production and export coordination
YUJU EnvironTech
High-Efficiency Rooftop HVAC Solutions for Global Projects
R32 | DC Inverter | 15/18 SEER2 | Heat Pump | Downflow | Horizontal | OEM & Project Support



Scan Contact Us