R32 & R454B Ducted Heat Pump Systems with Air Handlers
Side-Discharge R32 · Top-Discharge R454B · 24K–60K Capacity Classes · 208/230V Single-Phase · U.S. Applications
Explore two distinct ducted split-system platforms for U.S. residential and light-commercial HVAC requirements. YUJU offers R32 side-discharge and R454B top-discharge outdoor configurations with corresponding ducted air handlers, application-based product selection and OEM support.
Two outdoor-unit formats, two refrigerant platforms. The R32 side-discharge range and R454B top-discharge range are separate configurations. Their performance values, refrigerant circuits and matched indoor units must be evaluated independently; they should not be presented as interchangeable outdoor units.
1. Two HVAC Product Configurations
| Configuration | R32 Side-Discharge System | R454B Top-Discharge System |
|---|---|---|
| Refrigerant | R32 (A2L) | R454B (A2L) |
| Outdoor arrangement | Side-discharge condenser / heat pump | Top-discharge condenser / heat pump |
| Nominal product classes | 24K / 36K / 48K / 60K BTU/h | 24K / 36K / 48K / 60K BTU/h |
| Electrical supply | 208–230V / 1Ph / 60Hz | 208/230V / 1Ph / 60Hz |
| Indoor equipment | Ducted air handler with multi-speed ECM blower | Matched ducted air handler; blower specification subject to confirmation |
| Indoor external static pressure | Rated 0.5 in.w.c.; published range 0–0.8 in.w.c. | Maximum stated up to 0.8 in.w.c. |
| Expansion-control information | Indoor EEV and outdoor EEV listed | Indoor TXV and outdoor EEV listed |
| AHRI documentation | AHRI marked “Yes” in supplied R32 data; exact certified combination must be verified | AHRI status and reference numbers not provided in supplied R454B sheet |
R32 side-discharge outdoor configuration with a ducted indoor air handler for residential and light-commercial HVAC applications.
2. R32 Side-Discharge Heat Pump & Air Handler
The R32 side-discharge range is available in four capacity classes. The supplied specification identifies a multi-speed ECM blower, indoor and outdoor electronic expansion valves and a rated air-handler external static pressure of 0.5 in.w.c. (125 Pa), with a published operating range up to 0.8 in.w.c. (200 Pa).
| Capacity Class | Rated Cooling (BTU/h) | SEER2 | EER2 | Rated Heating (BTU/h) |
|---|---|---|---|---|
| 24K / 2 Ton | 24,000 | 18.8 | 13.4 | 24,000 |
| 36K / 3 Ton | 34,200 | 18.4 | 11.6 | 34,200 |
| 48K / 4 Ton | 48,000 | 18.0 | 11.4 | 48,000 |
| 60K / 5 Ton | 54,000 | 17.0 | 11.0 | 54,000 |
Cold-Climate Performance Reference
The R32 technical sheet also reports heating performance at 5°F (-15°C) and -13°F (-25°C). These are model-specific reference points, not a promise that every installation will deliver nominal capacity at every low-ambient condition.
| Capacity Class | Heating @ 5°F (BTU/h) | COP @ 5°F | Heating @ -13°F (BTU/h) |
|---|---|---|---|
| 24K | 24,000 | 2.3 | 16,500 |
| 36K | 26,500 | 2.2 | 20,300 |
| 48K | 36,000 | 2.4 | 28,500 |
| 60K | 39,700 | 2.4 | 29,800 |
Listed indoor airflow settings range from 485–994 CFM (24K) to 1,044–1,831 CFM (60K). Available airflow at a given duct pressure must be confirmed from the applicable blower performance information, rather than assuming the highest listed CFM is available at maximum static pressure.
3. R454B Top-Discharge Heat Pump & Air Handler
The separate R454B platform uses a conventional top-discharge outdoor arrangement. Its supplied indoor specification lists a TXV, while the outdoor unit lists an EEV. Both indoor and outdoor equipment are specified for 208/230V single-phase 60Hz electrical service.
R454B top-discharge outdoor configuration with a compatible ducted air handler; final system matching and certification documents are model-specific.
| Capacity Class | Rated Cooling @ 95°F (BTU/h) | SEER2 | EER2 | Heating @ 47°F (BTU/h) |
|---|---|---|---|---|
| 24K / 2 Ton | 24,000 | 18.0 | 10.5 | 25,000 |
| 36K / 3 Ton | 34,600 | 18.0 | 10.0 | 36,000 |
| 48K / 4 Ton | 46,000 | 18.0 | 10.0 | 47,000 |
| 60K / 5 Ton | 52,000 | 16.5 | 8.0 | 53,000 |
At an outdoor temperature of 5°F (-15°C), the supplied R454B top-discharge performance reference lists heating capacities of 17,800 / 26,800 / 36,000 / 38,000 BTU/h for the 24K / 36K / 48K / 60K classes, respectively, with a reported COP of 1.8 at that test point. These values should be confirmed against the final matched-system technical submittal.
4. Air Handler Selection: Airflow, ESP & Duct Compatibility
Selecting a ducted HVAC system requires more than choosing an outdoor unit by nominal tonnage. Air-handler airflow and external static pressure affect delivered capacity, acoustic performance and the real behavior of the refrigerant circuit.
- Airflow: review the required CFM for cooling, heating and any zoning strategy.
- External static pressure: confirm the blower performance at the actual duct, filter and coil resistance.
- Refrigerant system matching: verify indoor coil, metering device, pipe sizes and refrigerant compatibility.
- Electrical design: verify unit nameplate, MCA/MOCP and applicable circuit requirements for each indoor and outdoor unit.
- A2L design: review applicable refrigerant safety features, installation instructions and local code requirements.
- Installation arrangements: confirm cabinet orientation, condensate drainage and access clearances for the final model.
5. U.S. System Ratings & Certification Documentation
For American distributors and HVAC contractors, the decision should be based on the exact outdoor-unit and air-handler combination. YUJU can coordinate available product data, model matching and applicable certification information for the chosen system.
| Required Information | How It Is Handled |
|---|---|
| AHRI certified combination | R32 sheet indicates AHRI availability; specific AHRI reference and matched models must be confirmed before publication or customer quotation. The supplied R454B sheet contains no AHRI reference. |
| SEER2 / EER2 / HSPF2 | Use model-specific values from the applicable tested or certified combination and regional metric; never mix performance from different systems. |
| A2L safety and product listing | Confirm the final equipment configuration and applicable installation / safety documentation before offering compliance claims. |
| ENERGY STAR / cold-climate status | Verify the exact model combination in the current program database before adding logos or certification claims. |
| OEM / private label | Confirm any required changes to labels, documentation and certification / brand registration. |
6. Applications & Product Selection
- Residential ducted heat pump replacement: select the refrigerant platform and matched air handler according to local installation and performance requirements.
- New-build residential HVAC: coordinate capacity, duct design, return air, controls and cabinet dimensions.
- Light-commercial ducted projects: review operating hours, airflow, external static pressure and the required electrical service.
- OEM product lines: select consistent capacity classes and develop market-specific labels, documentation and packaging.
7. Need an R32 or R454B OEM Configuration?
YUJU can assist with product selection, application-specific configuration, quality requirements, OEM branding and technical documentation. For distributors developing a private-label HVAC range, explore our OEM Solutions for a broader view of product and market support.