Yuju EnvironTech Global HVAC Solutions
+86 571 86905176
Home > Products > R32 Residential Air Handler

R32 & R454B Ducted Heat Pump and Air Handler Systems | YUJU

YUJU RESIDENTIAL & LIGHT-COMMERCIAL HVAC PRODUCTS

R32 & R454B Ducted Heat Pump Systems with Air Handlers

Side-Discharge R32 · Top-Discharge R454B · 24K–60K Capacity Classes · 208/230V Single-Phase · U.S. Applications

Explore two distinct ducted split-system platforms for U.S. residential and light-commercial HVAC requirements. YUJU offers R32 side-discharge and R454B top-discharge outdoor configurations with corresponding ducted air handlers, application-based product selection and OEM support.

Two outdoor-unit formats, two refrigerant platforms. The R32 side-discharge range and R454B top-discharge range are separate configurations. Their performance values, refrigerant circuits and matched indoor units must be evaluated independently; they should not be presented as interchangeable outdoor units.

Choose the refrigerant platform and outdoor-unit layout first; then verify the matching air handler, electrical requirements, airflow and certified system combination.

1. Two HVAC Product Configurations

Configuration R32 Side-Discharge System R454B Top-Discharge System
Refrigerant R32 (A2L) R454B (A2L)
Outdoor arrangement Side-discharge condenser / heat pump Top-discharge condenser / heat pump
Nominal product classes 24K / 36K / 48K / 60K BTU/h 24K / 36K / 48K / 60K BTU/h
Electrical supply 208–230V / 1Ph / 60Hz 208/230V / 1Ph / 60Hz
Indoor equipment Ducted air handler with multi-speed ECM blower Matched ducted air handler; blower specification subject to confirmation
Indoor external static pressure Rated 0.5 in.w.c.; published range 0–0.8 in.w.c. Maximum stated up to 0.8 in.w.c.
Expansion-control information Indoor EEV and outdoor EEV listed Indoor TXV and outdoor EEV listed
AHRI documentation AHRI marked “Yes” in supplied R32 data; exact certified combination must be verified AHRI status and reference numbers not provided in supplied R454B sheet
YUJU R32 side discharge ducted heat pump outdoor unit with matching residential air handler 208 230V USA

R32 side-discharge outdoor configuration with a ducted indoor air handler for residential and light-commercial HVAC applications.

2. R32 Side-Discharge Heat Pump & Air Handler

The R32 side-discharge range is available in four capacity classes. The supplied specification identifies a multi-speed ECM blower, indoor and outdoor electronic expansion valves and a rated air-handler external static pressure of 0.5 in.w.c. (125 Pa), with a published operating range up to 0.8 in.w.c. (200 Pa).

Capacity Class Rated Cooling (BTU/h) SEER2 EER2 Rated Heating (BTU/h)
24K / 2 Ton 24,000 18.8 13.4 24,000
36K / 3 Ton 34,200 18.4 11.6 34,200
48K / 4 Ton 48,000 18.0 11.4 48,000
60K / 5 Ton 54,000 17.0 11.0 54,000

Cold-Climate Performance Reference

The R32 technical sheet also reports heating performance at 5°F (-15°C) and -13°F (-25°C). These are model-specific reference points, not a promise that every installation will deliver nominal capacity at every low-ambient condition.

Capacity Class Heating @ 5°F (BTU/h) COP @ 5°F Heating @ -13°F (BTU/h)
24K 24,000 2.3 16,500
36K 26,500 2.2 20,300
48K 36,000 2.4 28,500
60K 39,700 2.4 29,800

Listed indoor airflow settings range from 485–994 CFM (24K) to 1,044–1,831 CFM (60K). Available airflow at a given duct pressure must be confirmed from the applicable blower performance information, rather than assuming the highest listed CFM is available at maximum static pressure.

3. R454B Top-Discharge Heat Pump & Air Handler

The separate R454B platform uses a conventional top-discharge outdoor arrangement. Its supplied indoor specification lists a TXV, while the outdoor unit lists an EEV. Both indoor and outdoor equipment are specified for 208/230V single-phase 60Hz electrical service.

YUJU R454B top discharge heat pump outdoor unit paired with ducted residential air handler 208 230V

R454B top-discharge outdoor configuration with a compatible ducted air handler; final system matching and certification documents are model-specific.

Capacity Class Rated Cooling @ 95°F (BTU/h) SEER2 EER2 Heating @ 47°F (BTU/h)
24K / 2 Ton 24,000 18.0 10.5 25,000
36K / 3 Ton 34,600 18.0 10.0 36,000
48K / 4 Ton 46,000 18.0 10.0 47,000
60K / 5 Ton 52,000 16.5 8.0 53,000

At an outdoor temperature of 5°F (-15°C), the supplied R454B top-discharge performance reference lists heating capacities of 17,800 / 26,800 / 36,000 / 38,000 BTU/h for the 24K / 36K / 48K / 60K classes, respectively, with a reported COP of 1.8 at that test point. These values should be confirmed against the final matched-system technical submittal.

4. Air Handler Selection: Airflow, ESP & Duct Compatibility

Selecting a ducted HVAC system requires more than choosing an outdoor unit by nominal tonnage. Air-handler airflow and external static pressure affect delivered capacity, acoustic performance and the real behavior of the refrigerant circuit.

  • Airflow: review the required CFM for cooling, heating and any zoning strategy.
  • External static pressure: confirm the blower performance at the actual duct, filter and coil resistance.
  • Refrigerant system matching: verify indoor coil, metering device, pipe sizes and refrigerant compatibility.
  • Electrical design: verify unit nameplate, MCA/MOCP and applicable circuit requirements for each indoor and outdoor unit.
  • A2L design: review applicable refrigerant safety features, installation instructions and local code requirements.
  • Installation arrangements: confirm cabinet orientation, condensate drainage and access clearances for the final model.

5. U.S. System Ratings & Certification Documentation

For American distributors and HVAC contractors, the decision should be based on the exact outdoor-unit and air-handler combination. YUJU can coordinate available product data, model matching and applicable certification information for the chosen system.

Required Information How It Is Handled
AHRI certified combination R32 sheet indicates AHRI availability; specific AHRI reference and matched models must be confirmed before publication or customer quotation. The supplied R454B sheet contains no AHRI reference.
SEER2 / EER2 / HSPF2 Use model-specific values from the applicable tested or certified combination and regional metric; never mix performance from different systems.
A2L safety and product listing Confirm the final equipment configuration and applicable installation / safety documentation before offering compliance claims.
ENERGY STAR / cold-climate status Verify the exact model combination in the current program database before adding logos or certification claims.
OEM / private label Confirm any required changes to labels, documentation and certification / brand registration.

6. Applications & Product Selection

  • Residential ducted heat pump replacement: select the refrigerant platform and matched air handler according to local installation and performance requirements.
  • New-build residential HVAC: coordinate capacity, duct design, return air, controls and cabinet dimensions.
  • Light-commercial ducted projects: review operating hours, airflow, external static pressure and the required electrical service.
  • OEM product lines: select consistent capacity classes and develop market-specific labels, documentation and packaging.
Important: the two supplied residential product platforms use 208/230V single-phase power. The separate 460V three-phase commercial system belongs to a different product / application category.

7. Need an R32 or R454B OEM Configuration?

YUJU can assist with product selection, application-specific configuration, quality requirements, OEM branding and technical documentation. For distributors developing a private-label HVAC range, explore our OEM Solutions for a broader view of product and market support.

Request a Matched Heat Pump & Air Handler Proposal

Please provide the target market, refrigerant preference (R32 or R454B), capacity mix, voltage, indoor-airflow requirements, certification expectations, application and approximate order quantity. YUJU will review the appropriate equipment platform and available documentation.

Email: yuju201455@gmail.com | YUJU EnvironTech

Yuju Recommendation